Current File : /var/www/html/blog/wp-content/themes/amadeus/isolation.html |
<!DOCTYPE html>
<html lang="en">
<head>
<title>Single Phase/Three Phase Aircooled Isolation Transformers-Manufacturer in Chennai</title>
<meta http-equiv="Content-Type" content="text/html; charset=windows-1251">
<meta content="Vertex Power Solutions Private Limited manufactures single phase/three phase aircooled Isolation Transformers across Chennai in India" name="description" />
<meta content="air cooled single phase or three phase isolation transformer in chennai india,air cooled three phase isolation transformer supplier in chennai, three phase isolation transformer provider in chennai" name="keywords" />
<meta charset="utf-8">
<meta name="viewport" content="width=device-width, initial-scale=1">
<link rel="stylesheet" href="css/bootstrap.min.css">
<link rel="stylesheet" href="css/font-awesome.min.css">
<link href="css/jquery.atAccordionOrTabs.css" rel="stylesheet" type="text/css">
<link rel="stylesheet" href="css/animate.css">
<link rel="stylesheet" href="css/waves.min.css">
<link rel="stylesheet" href="css/style.css">
</head>
<body>
<header class="header">
<div class="header-container">
<nav class="navbar navbar-inverse custom-navbar">
<div class="navbar-header custom-header">
<button type="button" class="navbar-toggle" data-toggle="collapse" data-target="#myNavbar">
<span class="icon-bar"></span>
<span class="icon-bar"></span>
<span class="icon-bar"></span>
</button>
<a class="navbar-brand custom-brand" href="index.html"><img src="images/logo.png" alt="Servo Stabilizer Manufacturer in chennai"></a>
<div class="menulist">
<p>Solutions in Power Conditioning</p>
</div>
</div>
<div class="collapse navbar-collapse" id="myNavbar">
<ul class="nav navbar-nav navbar-right custom-nav">
<li><a href="index.html">Home</a></li>
<li><a href="aboutus.html">About Us</a></li>
<li class="active"><a href="products.html">Products</a></li>
<li><a href="solutions.html">Solutions</a></li>
<li><a href="downloads.html">Downloads</a></li>
<li><a href="testimonial.html">testimonial</a></li>
<li><a href="http://vertexpower.co.in/blog/">Blog</a></li>
<li><a href="contactus.html">Contact Us</a></li>
<!--<li class="icon"><a href="#"><i class="fa fa-search" aria-hidden="true"></i></a>
<div class="form-pos">
<input type="text" class="form-control" placeholder="search....">
</div>
</li>-->
<li class="icon"><a href="contactus.html"><i class="fa fa-envelope-o" aria-hidden="true"></i></a></li>
</ul>
</div>
</nav>
</div>
</header>
<!--header section-->
<!--about section-->
<section class="about-sec">
<img src="images/product-detail-banner4.jpg">
<div class="about-con">
<div class="container">
<!-- <h2>Products</h2>-->
</div>
</div>
</section>
<!--Clients section-->
<section class="pro-de-sec">
<div class="container pro-de-container">
<div class="pro-de-row">
<div class="pro-de-col">
<div class="pro-de-slide">
<div id="myCarousel2" class="carousel slide" data-ride="carousel">
<!-- Indicators -->
<!-- Wrapper for slides -->
<div class="carousel-inner" role="listbox">
<div class="item active">
<img src="images/iso1.png">
</div>
<div class="item">
<img src="images/iso2.png">
</div>
</div>
<!-- Left and right controls -->
<a class="left carousel-control" href="#myCarousel2" role="button" data-slide="prev">
<span class="glyphicon glyphicon-chevron-left" aria-hidden="true"></span>
<span class="sr-only">Previous</span>
</a>
<a class="right carousel-control" href="#myCarousel2" role="button" data-slide="next">
<span class="glyphicon glyphicon-chevron-right" aria-hidden="true"></span>
<span class="sr-only">Next</span>
</a>
</div>
</div>
</div>
<div class="pro-de-col">
<div class="pro-de-content">
<h1>ULTRA ISOLATION TRANSFORMER</h1>
<h3>SINGLE PHASE / THREE PHASE - AIRCOOLED</h3>
<h4>1 kVA - 500 kVA</h4>
<p>An isolation transformer is a transformer, often with symmetrical windings, which is used to decouple two circuits. An isolation transformer allows an AC signal or power to be taken from one device and fed into another without electrically connecting the two circuits. Isolation transformers block transmission of DC signals from one circuit to the other, but allow AC signals to pass. They also block interference caused by ground loops. Isolation transformers with electrostatic shields are used for power supplies for sensitive equipment such as computers, Lab Instruments, CNC Machines, Medical Equipments, etc.</p>
<p>
<strong>VERTEX Isolation Transformer</strong> employs a unique multiple shielding technique that reduces the interwinding capacitance to a large extent and increases the DC isolation.
</p>
</div>
</div>
</div>
</div>
</section>
<!--pro-tab section-->
<section class="pro-tab-sec">
<div class="container">
<ul class="demo">
<!--<li><a>TECHNICAL SPECIFICATION</a>
<section>
<table class="Features" width="100%" border="0" cellpadding="0" cellspacing="0">
<tbody>
<tr>
<td> </td>
<td> Smart Servo - not just a stabiliser </td>
</tr>
<tr>
<td> </td>
<td> <strong>Provides information for load & energy study.</strong>
<ul class="subUl">
<li> Voltage: I/P & O/P (L?L & L?N )</li>
<li> Current: O/P (R/Y/B)</li>
<li> Frequency</li>
<li> Status Indication: Overload/ Phase reversal/</li>
<li> Low Voltage/ High Voltage/</li>
<li> kVA (per phase), Avg kVA, KW (per phase), Avg KW</li>
<li> pf (per phase), Avg pf, kWh (per phase), Total kWh</li>
<li> Event recorder (Trip status ? Details of V & I with time)</li>
<li> Imax, Vmax & Vmin</li>
</ul>
</td>
</tr>
<tr>
<td> </td>
<td> User adjustable setting of O/P Voltage, High/Low cut-off limits & Manual / Auto Restart time delay, with great accuracy </td>
</tr>
<tr>
<td> </td>
<td >Event Recorder (Trip Status � Details of Voltage & Amps with time. </td>
</tr>
</tbody>
</table>
</section>
</li>-->
<li><a>TECHNICAL SPECIFICATIONS - ISOLATION TRANSFORMER</a>
<section>
<table width="100%" border="0" cellpadding="0" cellspacing="0" class="CustomDesigned">
<tbody>
<tr>
<td>TYPE OF TRANSFORMER </td>
<td>Dry Type, Floor Mounted, Indoor Application </td>
</tr>
<tr>
<td>TYPE OF COOLING </td>
<td>Naturally Air -Cooled </td>
</tr>
<tr>
<td>TYPE OF CONNECTION </td>
<td>Delta / Star </td>
</tr>
<tr>
<td>PRIMARY / SECONDARY VOLTAGE </td>
<td>i) 1:1 ii) 2:1 iii) Customised </td>
</tr>
<tr>
<td>REGULATION </td>
<td>< 3.5% </td>
</tr>
<tr>
<td>DUTY CYCLE </td>
<td>Continuous </td>
</tr>
<tr>
<td>CLASS OF INSULATION </td>
<td>Class F </td>
</tr>
<tr>
<td>TYPE OF LAMINATION</td>
<td>CRGO </td>
</tr>
<tr>
<td>AMBIENT TEMPERATURE </td>
<td>0 - 50� C </td>
</tr>
<tr>
<td>HUMIDITY </td>
<td>> 95% RH </td>
</tr>
<tr>
<td>DC GALVANIC ISOLATION </td>
<td>> 1000 M Ohms </td>
</tr>
<tr>
<td>DIELECTRIC VOLTAGE </td>
<td>2500 V for 2 min </td>
</tr>
<tr>
<td>LEAKAGE CURRENT </td>
<td>< 20 Micro Amps </td>
</tr>
<tr>
<td>COUPLING CAPACITANCE </td>
<td>0.001 PF </td>
</tr>
<tr>
<td>CMNRR </td>
<td>>100 dB </td>
</tr>
<tr>
<td>DEGREE OF PROTECTION </td>
<td>IP 31</td>
</tr>
<tr>
<td>CONSTRUCTION STANDARDS </td>
<td>As per IS: 2026 Part 1 & 11 </td>
</tr>
<tr>
<td>POWER FACTOR </td>
<td>0.75 Lagging to 0.75 Leading </td>
</tr>
<tr>
<td>STANDARD kVA RATINGS </td>
<td>1 kVA � 500 kVA </td>
</tr>
</tbody>
</table>
</section>
</li>
</ul>
</div>
</section>
<section class="broucher-sec">
<img src="images/broucher.jpg">
<div class="broucher-content">
<a target="_blank" href="pdf/isolation-transformers.pdf">DOWNLOAD BROCHURE</a>
</div>
</section>
<!--product2-->
<footer class="footer">
<div class="container footer-container">
<div class="footer-row">
<div class="footer-col1">
<h2>menu</h2> <ul class="list-inline custom-list">
<li><a href="index.html">Home | </a></li>
<li><a href="aboutus.html">About Us | </a></li>
<li><a href="products.html"> Products |</a></li>
<li><a href="">Solutions |</a></li>
<li><a href="downloads.html">Downloads |</a></li>
<li> <a href="contactus.html">Contact Us </a></li>
</ul>
</div>
<div class="footer-col2">
<h2>office</h2>
<h4>Vertex Power Solutions Pvt Ltd</h4>
<p>No. 14, Mosque Street, Easwaran Nagar, </p>
<p> Anna Salai, Pammal, Chennai - 600075,</p>
<p>Tamil Nadu, India</p>
</div>
<div class="footer-col3">
<h2>reach us</h2>
<p>+91 98860 81610 <span>/</span> +91 99400 58974</p>
<p>+91 - 44 - 6587 4772 <span class="break"></span>+91 - 44 - 2248 6452</p>
<p><a href="mailto:ho@vertexpower.co.in">ho@vertexpower.co.in</a> <span>/</span> <a href="">manjunath@vertexpower.co.in</a></p>
<p>Coimbatore - +91 98420 11833</p>
<p>Bangalore - +91 91646 57788</p>
</div>
</div>
<div class="footer-bot-sec">
<ul class="list-inline foot-list">
<li><a href="https://www.youtube.com/watch?v=dNve4Bn1_qI" target="_blank"><i class="fa fa-youtube"></i></a></li>
<!-- <li><a href=""><i class="fa fa-facebook"></i></a></li>
<li><a href=""><i class="fa fa-twitter"></i></a></li>
<li><a href=""><i class="fa fa-linkedin"></i></a></li>-->
</ul>
<div class="foot-div">
<p>CopyRight � Vertex Power Solutions Pvt Ltd 2017. All Rights Reserved</p>
<span> | </span>
<p>Designed & Developed by <a href="">Open Designs</a></p>
</div>
</div>
</div>
</footer>
<!-- <section class="pos">
<img src="images/banner.jpg">
<div class="pos-div">
</div>
</section> -->
<script src="js/jquery.min.js"></script>
<script src="js/bootstrap.min.js"></script>
<script src="js/jquery.multipurpose_tabcontent.js"></script>
<script src="js/jquery.bbq.js"></script>
<script src="js/jquery.atAccordionOrTabs.js"></script><script src="js/wow.js"></script>
<script src="js/waves.min.js"></script>
<script src="js/script.js"></script>
<script>
$(function() {
new WOW().init();
});
</script>
<script type="text/javascript">
$('.demo').accordionortabs();
</script>
<script>
(function(i,s,o,g,r,a,m){i['GoogleAnalyticsObject']=r;i[r]=i[r]||function(){
(i[r].q=i[r].q||[]).push(arguments)},i[r].l=1*new Date();a=s.createElement(o),
m=s.getElementsByTagName(o)[0];a.async=1;a.src=g;m.parentNode.insertBefore(a,m)
})(window,document,'script','https://www.google-analytics.com/analytics.js','ga');
ga('create', 'UA-69799376-2', 'auto');
ga('send', 'pageview');
</script>
</body>
</html>